ClickCease
Foundation Repair Detroit | Everdry Waterproofing       StablWall Reinforcing Fiber
Parameter Minimum Value Governing Test Method
Tensile Strength 500,000 psi ASTM D3039
Tensile Strain 1.5% ASTM D3039
Tensile Modulus 30,000,000 psi ASTM D3039
Color Black None
Roll Width 24 inches None
Roll Length 270 feet None

StablWall Adhesives: MINIMUM VALUES

PARAMETER StablWall Primer  StablWall Paste Filler StablWall Bonding Adhesive  Governing Test Method 
Color Part A Part B Mixed Amber Clear Amber Tan Charcoal Tan Amber Clear Amber None None None
Mix Ratio (Volume) Part A:Part B 3:1 3:1 3:1 None
Working Time @ 70 F 15 Minutes 30 Minutes 35 Minutes 1 Gallon Sample
Shelf Life 12 Months 12 Months 12 Months None
Tensile Strength 2,000 psi 2,000 psi 7,000 psi ASTM D638
Tensile Strain 0.30 0.05 0.03 ASTM D638
Tensile Modulus 100,000 psi 230,000 psi 400,000 psi ASTM D638
 Engineers and surveyors report by Kenneth Jensen & Associates, Inc. on the feasibility of using carbon fiber polymer sheeting on residential foundation walls is available by request. This report was prepared specifically for the StablWall product.